Main technical parameters
Valve function | 5V2 | ||
Reset method: air reset | Yes | ||
Reset method: mechanical spring reset | Yes | ||
Air port 1 vacuum operation | When using external pilot | ||
Design | Piston slide valve | ||
Sealing principle | Soft | ||
Drive mode | Electric | ||
Control method | Pilot | ||
Pilot air source | External | ||
Exhaust function | With flow control | ||
Hand control device | Optional non-locking | ||
Installation method | Installed on the manifold board | ||
Installation location | Arbitrary | ||
Switch position display | LED | ||
Air port 1,3,5,12/14,82/84 | On the road board | ||
Air port 2,4 | G¼ | ||
Product weight [g] | 320 | ||
Working and environmental conditions | |||
Valve function | 20 | 10 | 30 |
Working medium | Compressed air according to ISO 8573-1:2010 [7:4:4] | ||
Pilot medium | Compressed air according to ISO 8573-1:2010 [7:4:4] | ||
Working medium/pilot medium description | Can be lubricated (must always be lubricated once used) | ||
Work pressure Internal pilot [bar] | 1.5 … 8 | 1.5 … 8 | 3 … 8 |
Work pressure External pilot [bar] | -0.9 … 10 | -0.9 … 8 | -0.9 … 10 |
Pilot pressure4) [bar] | 1.5 … 8 | 3 … 8 | 3 … 8 |
Ambient temperature [°C] | –5 … +60 | ||
Medium temperature [°C] | –5 … +60 | ||
Electrical parameters | |||
Electrical connection | Via E-box | ||
Working voltage [V DC] | 24 ±10% | ||
Power consumption [W] | 1 | ||
Continuous power rate ED [%] | 100 | ||
Maximum switching frequency [Hz] | 3 | ||
Degree of protection according to EN 60529 | IP67 | ||
Valve switching time | |||
Valve function | 20 | 10 | 30 |
Switching time on [ms] | - | 13 | 20 |
Switch time off [ms] | - | 50 | 57 |
Conversion time [ms] | 15 | - | 31 |